HxCentral — Global Header
HxCentral

Reducing False Positives in HAI Surveillance

Aug 16, 2026 | Infection Control

Dr. Somayyah Hashmi,

Lead Solutions Consultant, HxCentral

Table of Contents

Key Takeaways

  • More alerts do not automatically improve infection prevention. Alert quality matters more than alert volume.
  • A single signal, such as a positive culture or antibiotic order, should not be treated as confirmed evidence of an HAI.
  • Reliable surveillance depends on accurate timing, device data, patient movement, laboratory results, and clinical context.
  • False positives often originate from weak source data and inconsistent documentation, not only from poor detection logic.

Automated healthcare-associated infection surveillance is often presented as a straightforward improvement over manual review.

Connect the hospital’s clinical systems, apply surveillance rules, generate alerts, and allow infection prevention teams to act faster.

In practice, the difficult part is not generating alerts. It is generating alerts that infection preventionists can trust.

A surveillance system that flags every positive culture, antibiotic order, device exposure, fever, or abnormal laboratory value may appear highly sensitive. But when these signals are presented without sufficient clinical context, the system can create a long queue of cases that do not meet the required surveillance definition.

The result is not simply an inefficient workflow. Repeated false positives can consume limited infection prevention capacity, delay the review of genuine cases, and gradually reduce confidence in the surveillance system itself.

The goal should therefore not be maximum alert volume. It should be dependable case identification.

A positive signal is not an HAI

Many false positives begin with an understandable design mistake: treating an isolated clinical event as evidence of an infection.

A positive blood culture may represent contamination. A urine culture may reflect asymptomatic bacteriuria rather than a catheter-associated urinary tract infection. Antibiotics may have been prescribed empirically and discontinued when infection was ruled out. Fever may be caused by surgery, medication, inflammation, or an underlying disease.

Each of these signals may justify review. None of them, independently, confirms an HAI.

Surveillance definitions require a combination of factors, which may include:

  • The timing of the event
  • The patient’s symptoms
  • Microbiology results
  • Device presence and duration
  • Location and transfer history
  • Imaging findings
  • Procedures and surgeries
  • Whether another infection source explains the result

When surveillance logic relies heavily on one or two data points, false positives are inevitable.

Hospitals should move away from single-trigger alerting and adopt multi-factor case identification. The system should evaluate the relationship between clinical events, not merely detect that those events occurred.

Timing is often where surveillance fails

HAI classification depends heavily on time.

The date of admission, date of event, device insertion date, procedure date, specimen collection time, symptom onset, and patient transfers can all affect whether an event is considered healthcare-associated and how it should be classified.

A surveillance engine may have access to all these data points and still produce poor results when the timestamps are incomplete, inconsistent, or interpreted incorrectly.

For example, a device may be documented in one clinical system but removed in another. A microbiology result may be finalised today even though the specimen was collected several days earlier. Symptoms may be recorded retrospectively in a clinical note. A patient may move between the emergency department, intensive care unit, and ward within a short period.

Without a reliable timeline, the system may associate an infection with the wrong care location, device, or reporting period.

Hospitals should treat temporal logic as a core surveillance capability, not a technical detail. Every alert should clearly show the sequence of relevant events so the infection preventionist can understand why the case was flagged.

Structured data alone is not enough

Electronic surveillance systems usually begin with structured data because it is easier to access and analyse.

Laboratory results, diagnosis codes, medication orders, device records, admission data, and procedure codes are valuable. But they rarely contain the complete clinical story.

Important evidence may remain in:

  • Nursing documentation
  • Operative notes
  • Radiology reports
  • Progress notes
  • Device insertion or removal notes
  • Infection prevention reviews
  • Clinician assessments

This creates a difficult balance.

A surveillance system that ignores unstructured clinical information may flag too many incomplete cases. A system that attempts to interpret every clinical note without strong governance may introduce a different type of inconsistency.

The practical approach is to use structured data for initial identification and clinical documentation for refinement. Technology should narrow the review population, assemble the supporting evidence, and present the relevant context. The final surveillance determination should remain visible and reviewable.

False positives are often a data-quality problem

It is tempting to respond to excessive alerts by adjusting the algorithm.

Sometimes that is necessary. But many alert-quality problems originate upstream.

Common causes include:

  • Missing device removal dates
  • Duplicate microbiology results
  • Inconsistent patient-location mapping
  • Delayed documentation
  • Incorrect specimen-source labels
  • Weak integration between laboratory and clinical systems
  • Inconsistent coding across facilities
  • Changes in EMR workflows that are not reflected in surveillance rules

An algorithm cannot consistently compensate for unreliable source data.

Before changing thresholds, infection prevention and technology teams should review whether the underlying clinical data is complete, timely, and correctly mapped.

This should not be treated as a one-time implementation exercise. Hospitals change laboratory systems, order sets, documentation practices, location codes, and clinical workflows. Surveillance rules must be reviewed whenever these changes occur.

Every alert should explain itself

A surveillance alert should not be a black box.

The infection preventionist should be able to see:

  • Which rule triggered the alert
  • Which clinical criteria are already satisfied
  • Which criteria remain uncertain
  • What evidence supports the alert
  • Which source systems supplied the data
  • Whether the case resembles a previously dismissed alert

This level of explainability serves two purposes.

First, it reduces review time. The user does not need to reconstruct the case manually across several systems.

Second, it enables improvement. When infection preventionists dismiss an alert, the organisation can understand why the alert was incorrect and refine the surveillance logic.

Without this feedback loop, the same false-positive pattern will continue to appear.

Not every possible case needs the same urgency

A surveillance platform should not present all alerts as equal.

Some cases may have a strong combination of symptoms, microbiology, device exposure, and timing. Others may be early signals with limited supporting evidence. A third group may be useful for monitoring but unlikely to meet a formal surveillance definition.

Placing all three in one queue forces the infection prevention team to perform the prioritisation manually.

A more effective model separates alerts by confidence and clinical importance.

For example:

  • High-priority cases with strong supporting evidence
  • Cases requiring specific missing information
  • Early-warning cases that need monitoring
  • Low-confidence alerts suitable for batch review

This does not mean suppressing uncertain cases. It means presenting uncertainty honestly and directing attention appropriately.

Local validation is essential

HAI surveillance cannot be deployed as a generic rule set and assumed to perform equally across every hospital.

Patient populations differ. Documentation practices differ. Laboratory workflows differ. Device utilisation differs. The same surveillance logic may perform well in one facility and poorly in another.

Hospitals should validate automated surveillance against infection preventionist-reviewed cases before relying on it operationally.

Validation should examine more than overall accuracy. It should assess:

  • Sensitivity: Are genuine cases being identified?
  • Positive predictive value: How many alerts are genuinely relevant?
  • Review burden: How many cases must be opened to find one true event?
  • Detection time: Is the system identifying risk earlier?
  • Performance by infection type, unit, and facility
  • Reasons for false-positive and false-negative results

The aim is not to prove that the technology works in general. It is to establish that it works within the hospital’s own clinical and data environment.

Recommendations for improving alert quality

Hospitals looking to reduce false positives should focus on five areas.

Strengthen case logic

Use multiple clinical and temporal criteria rather than isolated triggers. Surveillance definitions should be translated into transparent, testable workflows.

Improve data reliability

Review the completeness and consistency of laboratory, device, patient-location, procedure, medication, and clinical documentation data.

Show the evidence

Every alert should present the timeline, trigger, criteria, and supporting data required for review.

Prioritise intelligently

Rank cases by confidence, severity, transmission risk, and the urgency of intervention rather than displaying a flat alert list.

Learn from decisions

Capture why alerts are confirmed, rejected, or deferred. Use this feedback to improve rules, integrations, and documentation practices.

The right measure is not alerts generated

Hospitals should be cautious about evaluating surveillance technology by the number of cases it detects.

A system can generate more alerts without improving prevention.

More meaningful measures include:

  • Time from clinical signal to review
  • Time from review to intervention
  • Percentage of alerts requiring full manual investigation
  • Positive predictive value by infection type
  • Repeated false-positive patterns
  • Infection prevention hours saved
  • Corrective actions initiated and completed

These measures connect surveillance performance to the work infection prevention teams are expected to perform.

Better surveillance protects attention

Infection preventionists do not need another system that produces more work.

They need a system that brings the right cases forward, assembles the evidence, clarifies uncertainty, and helps them act sooner.

False positives will never disappear completely. Surveillance operates in a complex clinical environment where data can be incomplete and definitions require professional judgement.

But false positives can be controlled.

The answer is not simply more advanced detection. It is better-designed surveillance: clinically grounded, transparent, locally validated, continuously improved, and connected to action.

When alert quality improves, infection prevention teams spend less time dismissing noise and more time preventing harm.